A work group of Minnesota hospitals and health systems has developed a step-by-step protocol for preventing retained foreign objects. The protocol includes a detailed flow sheet with recommendations for each step. Processes are spelled out for performing and recording counts and taking x-rays, among other things.
The protocol is based on professional guidelines, including those from AORN, the American College of Surgeons, and others. It is also based on experience with adverse events re-ported as part of Minnesota’s mandatory reporting system In the state’s latest report re-leased in January 2008, 25 retained objects were reported in 2006-2007, down from 42 the previous year.
The evidence-based protocol was developed by a multidisciplinary group facilitated by the Institute for Clinical Systems Improvement (ICSI), Minneapolis, an independent nonprofit collaboration of medical groups, hospitals, and health plans.
The work group included representatives from nursing, surgery, radiology, patient safety and quality, and obstetrics and gynecology, plus a human factors consultant who has worked with OR teams. A separate protocol was developed for labor and delivery.
“We needed to balance patient safety with practicality, efficiency, and cost,” notes Dana Langness, RN, BSN, MA, a member of the work group and senior director of surgical services at Regions Hospital in St Paul.
Among the recommendations are:
The intent of red rules is to develop solid habits so the rules are followed consistently and accurately each time. Suggested red rules include:
The protocol recommends that the circulating nurse perform a room survey before the baseline count.
“The nurse methodically goes around the room, making sure nothing has been left in the room from the previous patient,” Langness explains.
The nurse verifies that the whiteboard and other recordkeeping documents are clean and don’t have information left from the previous case.
If the room survey or baseline count can’t be performed, the protocol states, the count is considered compromised. If the count is compromised, the regular count process should still be followed, but an x-ray should also be taken.
A baseline count is done before the patient is brought into the OR. If parallel processing is used—that is, room setup activities are carried out simultaneously—the protocol advises that 2 circulators be assigned to the room, one dedicated to the count process and the other for setup and patient care. If extra staff are not available, the protocol says the baseline count must be performed before the patient arrives in the OR.
The protocol advises using a preformatted whiteboard in each OR as the primary record for the count. Also, when possible, only one source of count information should be used during a case.
The advantage of a whiteboard is that every team member can see it, Langness notes. The board helps reinforce the importance of the count and serves as a memory aid. If the whiteboard is close to where the count is performed, the circulator can mark directly on the board rather than using a count sheet.
If the OR is too small for a whiteboard, the protocol recommends using a standardized, formatted count sheet. A sheet can also be used as a supplement to the whiteboard for procedures, such as cardiac cases, where there are a large number of items. (The protocol includes a sample count sheet.)
For ORs that have electronic displays, the count could be posted on the electronic display, Langness notes.
A methodical wound exploration should be performed with the count process, the protocol states. If this isn’t possible because of the patient’s condition, the exception should be documented and an x-ray taken as soon as possible based on the patient’s condition.
The protocol recommends keeping distractions and interruptions to a minimum during the count process.
Counting is “basically a sacred time, and all other distractions need to be minimized,” Langness comments.
The protocol says x-rays are not a substitute for counts and wound exploration. Langness says that after much discussion, the work group decided not to recommend that every patient have an x-ray to ensure nothing has been left behind.
The protocol advises that an x-ray be taken in the OR with portable equipment when:
The protocol includes recommendations for managing the x-ray process, including who should review the x-ray, timing, and communication issues.
Langness says her hospital is implementing the protocol in 3 phases.
“We’ve done a lot of work on preventing retained foreign objects here, but we’re starting over and taking it to a deeper level,” she says. “We have a strict process for how people are to count. We’re making sure people understand the correct process, as defined by the protocol. We’re making that a competency so everyone is on the same page.”
The first phase involved revising the count sheets so terminology and items counted are consistent with the protocol, standardizing the counting sequence, re-educating the staff, and standardizing placement of sharps and sponges on the Mayo stand and back table. The second phase will be to implement the room survey, use of 2 circulators during parallel processing, consistent wound exploration, and use of x-rays as recommended. The last phase will be to include the count documentation in Epic, the information system used for OR nursing documentation.
“Our vision is to have an electronic whiteboard some day where the nurse can enter the count, and it will go up on a screen for everyone to see,” Langness comments.
The protocol is at www.icsi.org. Look under Guidelines & More, then Patient Safety & Reliability.
Root causes of retained items reported by Minnesota hospitals:
Source: Minnesota Department of Health. Adverse Health Events in Minnesota. January 2008. www.health.state.mn.us/patientsafety