April 23, 2020

Experts address COVID-19 concerns in AORN town halls

By: Judith M. Mathias, MA, RN
Share

OR nurses are being asked to serve in positions outside the operating room and experiencing changes in their schedules, and they are concerned about the uncertainty surrounding the COVID-19 pandemic.

To support OR nurses during this time of crisis, AORN has been holding town hall Q&A webinars with infection preventionists, perioperative practice specialists, and other experts answering questions from OR nurses.

They include:

• Amber Wood, MSN, RN, CNOR, CIC, AORN senior perioperative practice specialist, and a Fellow of the Association for Professionals in Infection Control and Epidemiology

• Karen deKay, MSN, RN, CNOR, CIC, AORN perioperative practice specialist, and the AORN representative to the Centers for Disease Control and Prevention (CDC) Healthcare Infection Control Practices Advisory Committee

• Terri Link, MPH, BSN, CNOR, CIC, CAIP, FAPIC, AORN perioperative education specialist and infection preventionist

• Byron Burlingame, MSN, BSN, RN, CNOR, AORN senior perioperative practice specialist

• Julie Cahn, DNP, RN, CNOR, ACNS-BC, CNS-CP, AORN perioperative practice specialist

• Erin Kyle, DNP, RN, CNOR, NEA-BC, editor in chief, AORN Guidelines for Perioperative Practice, and the staff liaison to AAMI and ASTM

Lisa Spruce, DNP, RN, CNS-CP, CNOR

Lisa Spruce, DNP, RN, CNS-CP, CNOR, ACNS, ACNP, FAAN, AORN director of evidence-based perioperative practice, was the moderator and asked questions sent in by OR nurses.

Here is an edited version of some questions and answers from the March 26 and April 2 town halls.

 

What are hospitals around the country defining as urgent or emergency surgery?

deKay: Each hospital may already have established definitions that are part of their protocol for scheduling procedures. However, the urgency of a procedure must be evaluated on an individual basis by the surgeon, with consideration of the patient’s medical risk if the surgery were to be delayed, the geographical location (ie, if it’s in an area of high community spread), and the facility’s resources (ie, beds, staff, equipment, supplies).

In addition, AORN, the American College of Surgeons (ACS), and the American Society of Anesthesiologists (ASA) released a joint statement calling for the creation of a surgical review committee made up of representatives from surgery, anesthesia, and nursing leadership. The committee would meet daily to make case triage decisions for scheduled procedures, preferably no later than the day before surgery.

In conjunction with the statement, the ACS and surgical specialty societies prepared triage criteria according to specialty.

 

Is there any information or guidelines, which are evidence-based for intraoperative care of patients who are positive for COVID-19, that will protect staff and prevent transfer of the virus?

deKay: Minimizing the amount of equipment, supplies, and personnel in the room is one proven action to prevent transmission. However, each facility will need to develop its own protocol based on the number of ORs and negative pressure or airborne infection isolation rooms, the prevalence of disease in the region, and the availability of equipment and supplies.

When surgical procedures are performed on non-COVID-19 patients in the same surgical suite as those who have the virus, every effort should be made to distance the patients.

Some of the guidelines and protocols published by the ACS, Canadian Anesthesiologists Society, and Nebraska Medicine include:

• develop a dedicated COVID-19 OR

• have a dedicated OR team for COVID-19 patients with defined roles and responsibilities for each team member

• have dedicated surgical and anesthesia equipment and medication carts

• provide detailed education for the perioperative team on infection prevention strategies, including visual reminders

• if available, use a negative pressure anteroom with separate entrance between the OR and main hallway that can be used for donning and doffing personal protective equipment (PPE) and placing supplies that are needed after the case begins

• have a runner outside the OR to retrieve medication, instruments, and other supplies

• use mobile phones to request items from the runner and to notify the circulator when the items are available

• double-bag specimens.

 

Should COVID-19 precautions be used on all patients?

Cahn: The answer is more complicated than a yes or no. Ideally, screening patients for symptoms and history of exposure to positive COVID-19 patients should occur before scheduling surgery. However, there have been concerns about lab testing and asymptomatic patients. So depending on your local situation and patient population, it may be ideal to have everyone in the OR wear respiratory protection for all patients regardless of COVID-19 status.

This decision should take into account not only your N95 supply at the present time but also your projected usage because this shortage is expected to continue for months.

The CDC currently only recommends N95 use for known or suspected COVID-19 patients, and the use of N95s should be prioritized for these patients.

 

Should surgery on a COVID-19 patient be performed in a negative pressure OR?

Link: Normally the direction of airflow should be from the OR to the hallway (ie, positive pressure) to minimize contamination of the surgical field.

Some hospitals may have ORs with reversible airflow, others may have positive pressure ORs with negative pressure anterooms, and some may not have negative pressure rooms.

Precautions should be taken when performing aerosol-generating procedures, such as intubation, extubation, and bronchoscopy inspection of airways. The CDC states that these airflow-generating procedures should ideally take place in an airborne infection isolation room (ie, negative pressure). However, this negative pressure can put surgical patients at risk for surgical site infections (SSIs). An interdisciplinary team should perform a risk assessment to determine if surgery on a patient with suspected or confirmed COVID-19 can be postponed until the person is no longer infectious.

If it is determined that a negative pressure room will be used for a surgical procedure, it’s important to keep the doors to the room closed to minimize traffic in and out of the room, and, if possible, perform the procedure with as few people as possible. After the procedure, leave the room vacant while the OR air exchanges clear any airborne contaminants that may have remained in the room. These air exchanges should occur before anyone who is not wearing respiratory protection enters the room and before environmental cleaning is done.

Before converting an OR to negative pressure, consult with engineering and maintenance teams. They will help evaluate whether altering the pressure to negative might affect the air balancing in adjacent areas.

 

Can surgery on a COVID-19 patient be done in a positive pressure OR?

Link: Yes, a team may decide to use a positive pressure OR for a COVID-19 patient when there is an increased risk for an SSI or when converting an OR to negative pressure is not feasible or possible.

If possible, it is important that these procedures be performed with the least amount of people. In other words, this is a risk vs benefit decision that is specific to the situation, patient needs, and proximity of other patients in the OR.

Only essential personnel wearing respiratory protection, such as an N95 respirator or a powered air-purifying respirator (PAPR), should be in the OR during intubation and extubation, including the RN circulator. A time should then be established for when it is safe for other team members without respiratory protection to enter the room after intubation or extubation. This time should be determined in conjunction with facilities engineering personnel who know the air handling systems very well and who can provide information on the number of air exchanges for the room.

If a runner is used outside the OR to secure supplies, that person may wear a surgical mask but should not enter the OR. An anteroom or substerile room can be used as a drop-off point. Make sure one door is closed before the other is opened.

Other options include a portable high-efficiency particulate air (HEPA) filtration unit positioned near the patient’s breathing zone. The facilities engineering personnel can help with this placement. In addition, this portable unit can be turned off during the surgical procedure. A PAS [portable air scrubber]-HEPA combination unit also may be used in the anteroom.

After the procedure, adequate air exchanges should occur before environmental services staff enter the room for cleaning.

 

What is the recommended time lapse in an OR for proper reduction of airborne contaminants?

Burlingame: The amount of time it takes to clear the airborne contaminants is dependent on the number of air changes per hour.

According to the CDC, most ORs have either 15 or 20 air changes per hour, but some have more. Contact the facility’s maintenance or plant operations department to find out the number of air changes if not known.

The time it takes to achieve 99% efficiency at 15 air changes per hour is 18 minutes, and for 99.9% efficiency, it’s 28 minutes. If the air changes per hour are set at 20, the time required for 99% efficiency is 14 minutes, and for 99.9% efficiency, it is 21 minutes. More air changes per hour equals less time.

Another way to say this is the time it takes before personnel may enter the room without wearing respiratory protection. Cleaning should not occur while waiting for the air to be cleaned.

 

What doors should be opened for supplies?

Burlingame: It is key to keep door openings to a very minimum in both positive and negative pressure rooms. During the intubation and extubation process and for the number of minutes it takes to remove contaminants after intubation and after extubation, the door should remain closed at all times.

If the OR has two doors, one leading to the core and one leading to the hallway, either door may be opened, but think about it from this aspect: Which door would provide the least amount of airflow disruption? In some facilities, the door to the outer hallway is much larger than the one to the core, or it may be automated, which leaves it open longer than it takes to manually close the door to the core. In either case, the door to the core should be used except when it is necessary to move the patient through the door. The door should be opened only as far as necessary to bring in supplies.

 

What is the proper mask for performing a surgical procedure on a person under investigation or a confirmed COVID-19 patient?

deKay: If surgical N95 respirators are available, everyone in the room should be wearing them.

The CDC’s recommendations are that a respirator is preferred over a surgical mask when caring for a patient with known or suspected COVID-19. However, the CDC gives the option of wearing a surgical mask if a respirator is not available or because of supply shortages. The CDC also recommends prioritizing respirator use for those who will be present in the room during aerosol-generating procedures on symptomatic patients.

The World Health Organization (WHO) recommends using an N95 or equivalent respirator if aerosol-generating procedures are performed. Examples include intubation, extubation, bronchoscopy, open suctioning, bag masking, chest tube insertion, cauterization of blood vessels or gastrointestinal tissue, laparoscopy or endoscopy, intraoperative use of debridement devices with irrigation, and use of power equipment such as saws and drills.

WHO also says a PAPR is acceptable for respiratory protection, although the N95 respirator is preferred because the battery-powered blower in the PAPR filters the air inhaled but does not filter the air exhaled. This can increase the level of air contamination and increase the SSI risk. An interdisciplinary team, including an infection preventionist and occupational health professional, should determine whether a PAPR may be used when a sterile field is present.

The CDC does not recommend that PAPRs with exhalation valves be used during invasive procedures when a sterile field is present.

 

What is AORN’s view on cloth mask use if an OR runs out of surgical masks?

deKay: Cloth masks do not provide any protection as PPE and should not be worn by any healthcare professionals unless there are absolutely no masks or other respiratory protection left.

On March 24, the American Nurses Association released a position statement saying that “evidence does not support the notion that cloth masks are safe for healthcare personnel providing care to patients with coronavirus… as they do not afford the wearer any significant protection.”

Furthermore, the poor bacterial filtration of cloth masks may actually increase the patient’s risk for SSIs.

 

Hospitals in our area are disinfecting surgical masks using UV [ultraviolet] light. Is this safe? Does it in any way alter the integrity of the mask?

deKay: UV light is designed to disinfect surfaces once bioburden (eg, blood and dirt) has been removed. Manufacturers of single-use masks do not provide cleaning or disinfection instructions because the masks are intended for single use.

In addition, the permeability of the mask material can make effective cleaning difficult. Therefore, this strategy should be the absolute last resort because it can place healthcare personnel at risk for acquiring bloodborne-contact-droplet and airborne-transmissible infections, such as COVID-19, and increase the patient’s risk for SSIs when the reprocessed masks are worn in the OR.

 

What is the best way, if possible, to reuse a mask without risk of contamination?

deKay: Reuse of face masks is not safe and not commensurate with standards of care, and should only be considered in a crisis situation when other strategies have failed.

The decision to reuse face masks should be determined by occupational health, infection prevention, and professionals managing the facility’s respiratory protection program. It should also be based on prevalence of disease in the region, severity of illness, and local conditions (eg, number of disposable face masks available, current face mask use).

The CDC recommends that the reuse of face masks involve one healthcare provider using the same face mask for multiple patient encounters and removing it after each encounter.

Not all face masks can be reused. Face masks with ties may not be able to untie without tearing, so face masks with ear loops may be better for reuse.

Healthcare personnel should leave the patient area to remove their masks, folding them carefully and handling them by the strings and the outer edges so the outer surfaces are folded inward against themselves to reduce contact with the outer surfaces. The folded mask should then be stored in a clean closed paper bag or breathable container. Soiled or damaged masks should be discarded.

 

Does AORN have guidance on reuse of N95 respirators?

Wood: Reuse of N95 respirators is neither safe nor commensurate with standards of care and should only be considered in a crisis situation when other strategies to optimize respirator use have failed.

The CDC provides guidance on the reuse of N95 respirators; however, the maximum number of safe reuses cannot be assigned as a generic number because safe reuse is dependent on contamination over time.

Use of a cleanable face shield over the N95 is preferred over a surgical mask to reduce surface contamination.

Between uses, respirators should be hung in designated storage areas or kept in clean breathable containers such as paper bags.

 

Does AORN have guidance on extended use of N95s? Can N95s be covered to extend their use?

Link: The CDC and NIOSH [National Institute for Occupational Safety and Health] have released guidance on extended use of N95s. However, implementation of these strategies should be determined by occupational health, infection prevention, and professionals who manage a facility’s respiratory protection program.

Implementation also should be based on the prevalence of disease in the region, severity of illness, and local conditions (ie, number of respirators available and current use).

Extended use is preferred over reuse because it involves less touching of the respirator. However, if the respirator is contaminated with blood or other body fluids or has been used in aerosol-generating procedures, it should be discarded.

For safe extended use, the N95 must maintain its fit and function, and a face shield over the respirator is the preferred method to reduce surface contamination.

 

Can reusable gowns be used? What are the recommendations for reusable gown material, like thread count, type of cloth?

deKay: When supplies of isolation and surgical gowns are depleted, gown use can be shifted to cloth isolation gowns, which are usually made of polyester or polyester-cotton fabrics. These fabrics can be laundered, but additional laundry operations and personnel may be needed because of increased loads and cycles.

There should also be systems in place to routinely inspect and maintain these gowns.

The CDC has a document, “Considerations for Selecting Protective Clothing used in Healthcare for Protections against Microorganisms in Blood and Body Fluids,” which outlines the evidence, standards, test methods, and specifications for fluid resistance of impervious gowns that can be used as a guide.

 

What is the sequence for donning and doffing gowns and gloves for scrubbed and unscrubbed personnel caring for a COVID-19 patient?

Cahn: The sequence for donning and doffing of PPE for both scrubbed and unscrubbed personnel caring for a COVID-19 patient has not changed. The CDC recommends donning one set of gloves for unscrubbed personnel (www.cdc.gov/hai/pdfs/ppe/ppe-sequence.pdf). However, if a facility determines that they would like to implement the use of double gloving of unsterile gloves for unscrubbed personnel, they should consult with their infection prevention team to determine protocol and availability of resources before doing so.

 

What are some strategies for converting ORs to ICUs?

Link: This is a decision that should be made by an interdisciplinary team, which includes at least an infection preventionist, an anesthesia provider, and a facility’s management representative who is familiar with air handling in the perioperative department.

Some factors to consider are whether the positive pressure OR can be converted to a negative pressure room, whether adjacent ORs share the same air handling system, how close the converted ICU room is to the other ORs still being used for non-COVID surgery, and the availability of an anesthesia professional to manage equipment and ventilators.

 

How long does SARS-CoV-2 survive on surfaces?

deKay: SARS-CoV-2, the virus that causes COVID-19, can survive up to 3 hours in aerosols when air is not circulated or moving and up to 3 days on plastic and stainless steel. Therefore, sufficient air exchanges need to occur before cleaning begins, and thorough cleaning and disinfection of high-touch stainless steel surfaces is important.

The ASA suggests that it may be beneficial to use disposable covers, such as plastic sheets, to put over equipment to reduce droplet and contact contamination.

 

What is the frequency of high-touch surface disinfection that AORN is recommending for hospitals where a COVID-19 infection has been confirmed or suspected?

deKay: The current CDC guideline says routine cleaning and disinfection procedures using an EPA [Environmental Protection Agency]-registered, hospital-grade disinfectant on List N are appropriate for SARS-CoV-2 in healthcare settings.

It is important, however, that all items touched during patient care, as well as high-touch surfaces in the OR, are cleaned and disinfected after surgical procedures because of the potential spray of blood and body fluids.

Facilities may already have a policy and procedure for room cleaning after transmission-based precaution procedures, or an interdisciplinary team can be established to identify which surfaces to include and how often to clean them.

 

Should instruments be pretreated and remain in the room after the case for the entire time the room is closed to achieve 99% air exchange?

Kyle: The instruments may be pretreated and removed from the OR before extubation or other aerosol-generating procedures. If the instruments are removed after extubation or other aerosol-generating procedures, they should be pretreated and remain in the room until 99% of air exchanges have occurred. The time it takes for 99% of air exchanges to be completed is dependent on the air exchange rate of the room.

Once instruments are placed into a cart and the doors are closed, the outside of the cart should be wiped with disinfectant before being sent to sterile processing. For open carts, these should be covered with a clean disposable cover for transport from the OR to the decontamination area. If the patient is waking up and about to be extubated before the instruments have been pretreated and removed from the room, personnel who are not wearing respiratory protection while breaking down the field should leave the room during extubation and return after 99% of air exchanges have occurred.

 

Can scrub supplies and instruments be removed immediately after a procedure, or is it preferred that they remain in the room for a minimum time?

Kyle: It is preferred that the sterile field be broken down, pretreatment performed, and contaminated reusable instruments and devices be removed from the OR and transported to the decontamination area as soon as possible after the procedure. However, if the patient will be extubated before the instruments have been pretreated and removed, personnel who are serving that function should leave the room during extubation and wait for air exchanges to clear airborne contaminants before reentry into the room.

 

What PPE should personnel don when cleaning the OR after surgery on a COVID-19 patient?

Link: Once sufficient time has elapsed to remove infectious particles, cleaning personnel should perform hand hygiene and then don gowns and gloves. A facemask and eye protection should also be worn if splashes or sprays are anticipated during cleaning or if they are required by disinfectant instructions for use (IFU). Shoe covers are not necessary as part of PPE.

 

Our hospital-grade, EPA-registered disinfectant supply is running low. We will not receive another shipment for 2 weeks. Is there an alternative EPA-registered disinfectant, or can we make our own?

Wood: The EPA website has a list of disinfectants that have qualified under its emerging pathogen viral pathogens program for use against SARS-CoV-2.

Another option is to contact local health authorities for guidance or access to stockpile resources.

When an EPA-registered product is not available, the CDC allows for the use of generic sodium hypochlorite solutions, using a 1:100 dilution (500-615 ppm). However, it is important to note that this solution is not a cleaning agent and can be both caustic and corrosive, especially on stainless steel surfaces. All soil should be removed from the surface before applying this solution.

Also, the solution can cause respiratory symptoms in personnel who are using it, and it should be used with caution and in well-ventilated areas.

 

Are there any special considerations for cleaning, decontaminating, and sterilizing surgical instruments that have been used for a patient with suspected or confirmed COVID-19?

Link: There are no special considerations. Instruments and devices that have been used in procedures for patients with known or suspected COVID-19 should be handled the same as other instruments.

Reprocessing should follow the manufacturer’s IFU and be consistent with recommendations in the AORN Guideline for Cleaning and Care of Surgical Instruments.

 

Are there any special decontaminating and cleaning procedures for reusable laryngoscopes used for COVID-19 positive patients?

Wood: There are no special or additional considerations. Care of laryngoscopes should be according to the manufacturer’s IFU and the AORN Guideline for Cleaning and Care of Surgical Instruments.

The COVID-19 virus is an enveloped virus, and it is susceptible to those EPA-registered disinfectants used in the healthcare setting.

 

Has there been any guidance on the use of rigid or flexible esophagoscopes for COVID-19- positive or suspected patients?

Kyle: In the same way as surgical instruments, these should be handled according to the manufacturer’s IFU and in a manner that is consistent with the AORN Guideline for Flexible Endoscopes. Channeled flexible endoscopes are known to present unique decontamination challenges. It is essential that esophagoscopes and all endoscopes undergo point-of-use treatment and proper decontamination as soon as possible after use.

 

What are the recommendations for continued cleaning of ambulatory surgery centers (ASCs) while closed because of the coronavirus?

Wood: ORs can be cleaned before they are shut down. Likely, it is unknown when a center is going to reopen, and facility staff may not be allowed to return until restrictions for COVID-19 have been lifted.

When the ASC does reopen, ORs should be terminally cleaned, and supplies and equipment should be evaluated for signs of contamination.

 

For ASCs closed because of COVID-19, what is the process that should be performed before reopening, for example, the sterilizers, OR temperatures, and refrigerated medications?

deKay: There are several things to consider before shutting down and reopening an ASC. If it is to be shut down for an indefinite period, take inventory of the equipment and supplies, including expiration dates.

This will help determine which supplies could be used by a hospital in the event of shortages and which supplies will need to be restocked or retrieved before the ASC is reopened.

The following should be considered when closing down and reopening an ASC:

• Determine if equipment or supplies will be affected by temperature and humidity, per the manufacturer’s IFU.

• If utilities are shut down, determine if freezers that contain tissue and refrigerators that contain medications will be transferred to another facility.

• Autoclaves will have to be brought back up before procedures can begin again, and qualification testing may need to be conducted per the manufacturer’s IFU and may involve industry service technicians.

• Before HVAC [heating, ventilation, and air conditioning] is restored, the facility will need to be cleaned. If dust is found on surfaces, it can be dispersed into the air after HVAC is restored. After a complete air exchange has occurred, a terminal cleaning will need to be done and supplies evaluated for contamination.

• If utilities are shut down, HVAC should be monitored for variances in temperature and humidity. ✥