April 3, 2012

Joint Commission’s top ten toughest standards

By: OR Manager
PDF
Share

What’s on the Joint Commission’s list of problem standards? The top 10 scored standards didn’t change much in 2011. Five of the top 10 are Environment of Care/Life Safety issues.

Here’s a look at the trouble spots as identified at the Joint Commission’s executive briefing in late 2011.

 

Medical Records: RC.01.01.01

Sign, date, and time of medical record entries are still the main issues with this standard. The Joint Commission noted that it is looking at signature stamps to ensure that stamps only prompt a “fill-in-the-blank” template and do not create a stamped signature.

The Joint Commission is also looking for the same handwriting on the date/time/signature to ensure others are not completing the date and/or time. Also scored under this standard is legibility and ensuring that information in the medical record justifies care/treatment and service.

 

Life Safety: LS.02.01.20

Corridor clutter is the biggest issue Life Safety Code (LSC). The Joint Commission suggests that you review and appropriately update your building drawings. Often, the LSC drawings don’t reflect changes to the building, or don’t identify areas such as the ICU or the OR as “suites,” which allow some leeway for hallway storage.

Remember, too, that the Joint Commission allows crash carts, isolation carts, and chemo carts to be considered “in use” in hallways. Linen hampers and latex carts are not allowed in hallways for more than 30 minutes, or they will be scored. Additionally, if you have hallway beds, surveyors will score the obstruction caused by these beds under this standard. Surveyors are trained to look at clutter in a hallway and revisit it an hour or so later; if it is still there, they score it.

Helpful tips:

• Dead-end corridors of less than or equal to 50 square feet can be used for storage.

• Hospitals are allowed to use a patient room for storage if there is an automated door closure and if it is fully sprinklered.

It may be necessary for hospitals to request an equivalency for this if the perimeter walls in these storage locations do not fully extend from floor deck to ceiling deck.

 

Life Safety: LS.02.01.10

For fire walls, penetrations are still a big problem; IT cables are the biggest offender. Also frequently scored are fire doors that do not close and latch properly or have too large of a gap between leaves or at the base. When surveyors find adhesive tape over the latch to prevent a fire door from latching, it is scored here.

 

Life Safety: LS.02.01.30

For smoke walls, again, penetrations are a frequently scored item. Surveyors also score when doors to hazardous areas do not properly latch, due again to improper use of tape over the latch or a need for maintenance to correct alignment or closure pressure. Hazardous areas also need signage to allow access only to appropriate people. The hospital can decide which of these rooms need to be locked through a risk assessment, though some states require that they be locked.

 

Environment of Care: EC.02.03.05 and EC.02.05.01

Surveyors were trained in 2011 on these standards, which include the requirements for quickly producing thorough documentation of life safety and utility systems inspections and testing. Surveyors are scoring EC.02.05.01 when there is no written inventory of components of utility systems or when these utilities are not maintained in a timely manner.

The hospital must define the frequency for maintaining, testing, and inspection of utility systems. The Centers for Medicare and Medicaid Services (CMS) has agreed with the Joint Commission that intervals for testing and inspection may be based on hospital experience, risk levels, and current literature as well as manufacturers’ recommendations.

 

Infection Prevention and Control: IC.02.02.01

Three conditions of participation (CoPs) are associated with this standard. The Joint Commission noted that every clinical area included under the hospital’s CCN [CMS certification number] should be covered by the infection control plan and risk assessment.

This standard can result in a condition-level deficiency and perhaps an Immediate Threat to Health or Safety finding.

 

Disinfection practices

The most problematic issue is intermediate and high-level disinfection.

Surveyors are scoring when staff are not well trained (say or do things contrary to policy), usually because they lack sufficient oversight. For example, staff are seen estimating the concentration of disinfectant; are not documenting the quality controls (for instance, on glutaraldehyde test strips); or are not following manufacturers’ instructions.

 

Endoscopes

Endoscopes remain a hot issue. Surveyors are still seeing storage of endoscopes with the tip resting on a dirty towel or Chux. The Joint Commission also requires that all scopes, including loaners, be put on the biomed inventory list to provide more oversight for the process.

 

Low-level disinfection

A continued trouble spot is leaving the disinfectant on surfaces or pieces of equipment for the recommended drying time. Follow manufacturers’ recommendations and consider drying time in product selection and staff education on product use.

 

Personal protective equipment

Surveyors are noting that personal protective equipment (PPE) is a problem; sometimes no PPE are available, or staff are reusing PPE.

This is where wearing a surgical mask around the neck outside the OR would be cited. Also, this standard is scored when surveyors discover during their tracer that a patient should be on isolation precautions and is not.


 

—John Rosing, MHA, FACHE


 

Medical Records: RC.02.03.07

Verbal order authentication within 48 hours or per state law is still an issue. We thought electronic medical records would help with this. But we are seeing hospitals struggling with this issue when a hard stop is not in place to obtain required authentication. Recall that CMS allows partners of physicians who gave the verbal order to authenticate the order; however, this exemption is due to expire in 2012. CMS has proposed new rules that would extend this exemption indefinitely.

 

Medication Management: MM.03.01.01

Requirements of this standard have been among the top scored for a decade or more. Problems continue to be:

• monitoring your medication refrigerator according to your policy

• lack of staff action when there are temperature outliers (even if that action is to return to the refrigerator an hour later to retest the temperature, which by this time may have returned to be within the desired range).

Define in policy nonlicensed staff who can have access to areas where medications are stored, and educate those staff about their responsibilities. Create reasonable policies. For example, you can allow housekeeping personnel in the OR incidental access to medications, but this must be both allowed by policy, and the staff must be informed of this responsibility.

Surveyors are still finding and citing medication carts, medication tackle boxes, or supplies containing medications in unlocked, unoccupied areas.

They are citing hospitals when staff leave the hospital’s employment but do not have their access password promptly removed from automated dispensing machines.

The Joint Commission reinforced that the beyond-use date must be displayed on multidose vials. Hospitals must follow the manufacturer’s instructions if they differ from the 28-day rule.

(The 28-day rule does not apply to vaccines, but the Joint Commission advised that hospitals adhere to the “cold chain.” In other words, vaccines need to be at the appropriate temperature throughout the product life.)

Lastly, the element of performance related to expired medication is still a problem.

 

Provision of Care: PC.01.02.03

The top issues scored under this standard are initial assessments done per policy and the update to the history and physical (H&P). The Joint Commission noted that the H&P must be no older than 30 days, and when performed and documented prior to an admission, needs to be updated within 24 hours of the admission—but always before any procedure is performed (ie, whichever comes first: 24 hours or a procedure).

This update has to include language that the H&P has been reviewed, the patient has been “examined,” and either there were no changes or if there were changes, the changes must be noted; CMS is not wavering on this requirement. ❖

 

John Rosing can be reached at 262/242-3631 or johnrosing@pattonhc.com.