Third in a series on managing bone allografts. In the October issue, articles included were Allografts: Overview of the process; and Donor screening: First step in safety. In the November issue, articles included Help in evaluating bone allografts; Bone allografts: Options for healing; and Making good choices of DBM products.
Tissue cleaning and sterilization provide an additional level of safety beyond donor screening and procurement for preventing the transmission of infection from allografts. Tissue processors need to strike a fine balance between eliminating microorganisms and preserving the integrity and quality of the graft. This is an overview of tissue cleaning/disinfection and sterilization methods with suggestions for evaluating processing claims.
Tissue processing is defined by the American Association of Tissue Banks (AATB) as “any activity performed on tissue, other than tissue recovery or collection, including preparation, preservation for storage, and/or removal from storage, to ensure the quality and/or sterility of human tissue. Processing includes steps to inactivate and or remove adventitious agents.” (“Adventitious” refers to agents that occur sporadically and are not inherent or innate.)
Sterilization methods can often be completed during tissue processing with cleaning and disinfection steps or in the allograft’s final packaging with terminal sterilization. Sterilization is defined by the AATB as “a validated process used to render tissue free from all viable microorganisms, including spores.” If a sterilization step is employed by the tissue supplier, the process must be validated, a sterility assurance level must be set, and the process must reduce the allograft bioburden to the set level in its final packaged form.
Tissue banks use proprietary methods to process and sterilize tissue and must independently validate the processes employed. The US Food and Drug Administration (FDA) does not require tissue to undergo sterilization. The FDA and AATB do not recommend specific tissue processing or sterilization methods but state that all tissue processors must validate all tissue processing methods used.
Tissue processors must also ensure that cleaning/disinfection and sterilization methods maintain the tissue’s mechanical and biological integrity. An allograft’s strength is more important in some tissue forms than others. For example, soft tissue allografts must maintain strength to support the repair or replacement of the patient’s own tissue. Strength is also critical when cortical bone is used in load-bearing applications, such as in spine surgery and large joint reconstruction.
Common chemical methods for cleaning/disinfecting allograft tissue use aqueous solutions of detergents or surfactants, hydrogen peroxide or other peroxides, organic solvents, acids, and alcohol. Chemical methods are often combined with mechanical methods. These processes must:
Certain processing methods may have more deleterious effects on tissue properties than others. For example, extended exposure to hydrogen peroxide can significantly reduce the osteoinductivity of cortical bone; that is, the graft’s ability to induce the growth of new bone cells (DePaula et al, 2005).
Sterilization of allograft tissues is a controversial area. It is difficult to sterilize many allograft tissues because of their sensitive structure and components. It is also challenging to remove all of the potential organisms within tissue without disrupting the allograft’s biological and structural integrity. The issue becomes even more challenging as technology advances, and tissue banks introduce more “fresh” or cellular tissue forms. Because cells cannot withstand sterilization, some tissue banks rely on donor screening and mild processing techniques to maintain safety.
Asking questions of your tissue bank can help in understanding the complex relationships between tissue banks, tissue processors, and distributors. Hospitals should set criteria for evaluating tissue suppliers (sidebar, p 16).
More information on evaluating processing and sterility claims and on developing criteria for tissue suppliers are in Hospital Tissue Management: The Practitioner’s Handbook by the American Association of Blood Banks, AATB, and the Eye Bank Association of America.
The handbook advises that criteria include whether the tissue supplier’s facility and all related processors and intermediaries:
Among other attributes the handbook suggests considering:
The handbook also recommends asking for a tissue processor’s inspection findings; FDA warning letters, if any; and any other related communications. This information can be requested from the FDA directly. Warning letters are posted at www.fda.gov
Thomas E. Mroz, MD, a spine surgeon, and his colleagues in a 2008 article suggested questions to ask of tissue banks. Among these are: Is the graft at risk of being structurally or biologically compromised because of the type of sterilization? Does the bank validate its technique? Is there a sterility assurance level?
The safety and quality of the allograft are related not only to processing and sterilization but also to the initial donor screening and selection. The more stringent a tissue bank’s donor criteria, the gentler it can be on cleaning and disinfection, and the more biological properties the tissue maintains.
Ultimately the techniques the tissue bank employs must yield safe, effective allografts that are processed and validated to maintain the tissue’s natural function to ensure the best possible outcome for recipients.
–Joel Osborne
Vice President, Quality Assurance and Regulatory Affairs
Musculoskeletal Transplant Foundation
This series is a collaboration between OR Manager and the Musculoskeletal Transplant Foundation.
American Association of Blood Banks, American Association of Tissue Banks, Eye Bank Association of America. Hospital Tissue Management: A Practitioner’s Handbook. Bethesda, MD: AABB, 2008. www.aabb.org
American Association of Tissue Banks. AATB Standards for Tissue Banking. McLean, VA: AATB, 2008. www.aatb.org
Aspenberg P, Johnsson E, Thorngren K G. Dose-dependent reduction of bone inductive properties by ethylene oxide. J Bone Joint Surg Br. 1990;72:1036-1037.
Association for the Advancement of Medical Instrumentation. Technical Information Report TIR37:2007: Sterilization of health care products—Radiation—Guidance on sterilization of human tissue-based products. Arlington, VA: AAMI, 2007. www.aami.org
Currey J D, Foreman J, Laketic I, et al. Effects of ionizing radiation on the mechanical properties of human bone. J Orthop Res. 1997;15:111-117.
DePaula C A, Truncale K G, Gertzman A A, et al. Effects of hydrogen peroxide cleaning procedures on bone graft osteoinductivity and mechanical properties. Cell Tissue Bank. 2005;6:287-298.
Ijiri S, Yamamuro T, Nakamura T. Effect of sterilization on bone morpho-genetic protein. J Orthop Res. 1994;12:628-636,1994.
Mroz T E, Joyce M J, Steinmetz M P, et al. Musculoskeletal allograft risks and recalls in the United States. J Am Acad Orthop Surg. 2008;16:559-565.
Sterilization is measured by a sterility assurance level (SAL), which the Association for the Advancement of Medical Instrumentation (AAMI) defines as the probability of a single viable microorganism remaining on an item after sterilization. AAMI states that an SAL of 10-6 is appropriate for medical devices, equating to a 1 in a million chance that a viable microbe remains on the device. AAMI also says that this level of sterility is appropriate if the medical device can withstand these sterilization methods without adversely affecting its essential safety and function.
The FDA considers an SAL of 10-3 appropriate for biologic medical devices, which is an estimated 1 in 1,000 probability of the presence of a viable microbe (AAMI, 2007).
The FDA does not require a specific SAL level for tissue banks; however, both the FDA and the AATB state that if a sterilization process is used, and an SAL is claimed, it must be validated.
There are 2 methods to validate sterility of tissue:
The first method is per the US Pharmacopia (USP) guidance that governs sterilization for pharmaceutical-grade medical products that cannot undergo terminal sterilization (eg, injectable medications and sterile solutions). A tissue bank may choose to clean, disinfect, and aseptically process bone and soft tissue rather than use terminal sterilization because of the potential deleterious effect of terminal sterilization on tissue.
The tissue bank uses a validated cleaning and disinfection method with strict adherence to aseptic technique.
Sterility testing is then performed on the processed tissue in accord with the USP <71> Sterility Test. The test demonstrates that the tissue itself is not inhibitory to the growth of microbial contaminants. Tissue that is processed through aseptic means and passes all of the appropriate testing related to the USP guidance can be labeled as “sterile per USP.”
In terminal sterilization, tissue is sterilized in its final package. Many tissue banks use a terminal sterilization step and claim to achieve a SAL of 10-6. If this claim is validated, the FDA allows the bank to use the word “sterile” on its packaging.
Allografts may be terminally sterilized by several methods, including ethylene oxide, gamma radiation, electron (E)-beam radiation, and hydrogen peroxide plasma.
The most common sterilization technique used for tissue is gamma radiation. Many tissue banks use a low to moderate dose of gamma radiation to sterilize their tissues in their final packaging. High levels of gamma radiation have been shown to be detrimental to tissue integrity (Currey et al, 1997; Ijiri et al, 1994). Ethylene oxide has also been associated with negative effects on human tissue properties (Aspenberg et al, 1990).
The tissue bank should provide the hospital with detailed data on the effects of its sterilization method on tissue integrity.
Some questions to ask tissue suppliers:
Source: Musculoskeletal Transplant Foundation.