Bacterial contamination is common on the hands of anesthesia providers, with high rates of transmission to the surgical field, a new study finds. “As anesthesiologists, we like to think the surgical drapes protect the patient from tens of trillions of microorganisms that are in and on our bodies. Nope!” says Steven L. Shafer, MD, of Columbia University and editor of Anesthesia & Analgesia, which published the report in its January 2011 issue.
Studying the origin of bacteria transmitted to the surgical field in 164 operations performed under general anesthesia, the researchers found that in 11.5%, the bacteria were transmitted to the stopcock valves of the IV lines. In nearly half of these cases (47%), the bacteria in the IV lines were the same as those on the hands of anesthesia providers, including attending anesthesiologists, residents, and nurse anesthetists.
In 66% of the cases, potentially pathogenic bacteria were found on the anesthesia providers’ hands before the operation.
Overall, bacteria were transmitted to the intraoperative environment in 89% of the procedures. In 12%, anesthesia providers’ hands were the source.
Transmission was more likely when the anesthesiologists supervised more than one room, patients were older, and patients were sent directly from the OR to the ICU.
“These findings support initiatives designed to improve intraoperative hand hygiene of anesthesia providers both before and during patient care, as well as intraoperative decontamination strategies,” says Randy W. Loftus, MD, of Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire, who led the study.
Interestingly, there was a 90% reported compliance with perioperative hand hygiene during the study. The authors think the hand contamination was likely due to ineffective hand decontamination even though hand hygiene was performed.
All of the anesthesia providers had access to hand hygiene devices, including a wall-mounted 60% alcohol dispenser upon entry into the OR and a 70% alcohol dispenser on the anesthesia cart.
Like similar reports, “this study suggests that there is a need for further education even at the level of experienced health care providers,” the authors say.
In an earlier study, the authors showed that potentially pathogenic bacteria, including multidrug-resistant bacteria, are transmitted both to patients and the immediate intraoperative patient environment during general anesthesia. Intraoperative sites observed were the adjustable pressure limiting (APL) valve and agent dial on the anesthesia machine. Increasing contamination of the intraoperative environment was in turn associated with an increased risk of patient contamination of the stopcock set, and contamination of the stopcock sets was associated with a significant increase in patient mortality.
Loftus R W, Koff M D, Burchman C C, et al. Transmission of pathogenic bacterial organisms in the anesthesia work area. Anesthesiology. 2008;109:399-407.
Loftus R W, Muffly M K, Brown J R, et al. Hand contamination of anesthesia providers is an important risk factor for intraoperative bacterial contamination. Anes Analg. 2011;112:98-105.