May 17, 2017

Consider a sterilization subject matter expert to increase compliance

By: Susan Klacik, BS, ACE, CHL, CRCST, FCS
Share

Compliance with sterilization and disinfection standards is critical to patient safety, yet Joint Commission surveyors continue to cite healthcare facilities for noncompliance with high-level disinfection (HLD) and sterilization processes during accreditation surveys. Organizations with HLD and/or sterilization breaches during a survey may receive an immediate threat to life or adverse accreditation decision.

Noncompliance findings include:

• failure to test high-level disinfectants for the minimum effective concentration

• not following the medical device instructions for use (IFUs) for cleaning or sterilization, improper processing, transport, and/or storage of flexible endoscopes

• incomplete records for sterilization or HLD

• inappropriate equipment transportation

• inability to demonstrate adequate training and competency of staff performing sterilization or HDL tasks.

In September 2016, the need for a subject matter expert (SME) in sterilization and disinfection was discussed at the Medical Technology and Healthcare-Associated Infections conference. Leaders in infection prevention and control from the Association for the Advancement of Medical Instrumentation (AAMI), American Hospital Association, Centers for Disease Control and Prevention (CDC), Food and Drug Administration’s Center for Devices and Radiological Health (FDA/CDRH), and the Joint Commission met to identify the causes of healthcare-associated infections (HAIs) and find ways to reduce those related to medical devices.

In a published report from the conference, they concluded: “As technology advances, medical devices are growing more sophisticated. The increase in complexity requires a corresponding increase in the level of knowledge and skills to safely use, manage, and reprocess the device. However, specialized cleaning and processing resources may be unavailable within a facility.”

 

SME role and responsibilities

To meet the new demands of the constantly changing healthcare regulations, organizations need a subject matter expert for sterilization and disinfection. The SME’s main responsibility is to know the current regulations, standards, and guidelines and to help ensure the healthcare system’s compliance.

The SME, who may be a manager, supervisor, or educator, can conduct audits to ensure best practices are being followed, such as reducing the need for immediate use steam sterilization during surgery, using the appropriate disinfection processes, and verifying that processing practices meet the requirements for new products.

To be effective, SMEs must keep up to date on the latest standards and guidelines. They need access to the most current technical publications, such as:

• the International Association for Healthcare Central Service Materiel Management’s (IAHCSMM’s) Central Service Technical Manual, eighth edition

• AAMI standards and technical information reports

• AORN guidelines.

Local and national professional conferences, seminars, and workshops on sterilization and HLD are invaluable resources for education and networking with peers. Most importantly, the SME can benefit healthcare facilities by ensuring that the sterilization team is consistently using best practices for medical device processing.

 

Joint Commission standards

The need for a SME is also suggested in the Joint Commission’s Standard and Elements of Performance (EP) Standard HR. 01.06.01: Staff are competent to perform their responsibilities.

• EP1. The facilities define the competencies it requires of its staff.

• EP3. An individual with the educational background, experience, or knowledge related to the skills being reviewed assesses competence.

• EP 15. The organization takes action when a staff member’s competence does not meet expectations.

The primary standard governing HLD and/or sterilization processes for all settings is the Joint Commission’s Infection Control Chapter IC.02.02.01: The critical access hospital reduces the risk of infections associated with medical equipment, devices, and supplies.

Healthcare organizations accredited by the Joint Commission continue to have serious noncompliance issues with this standard. Since 2009, the annual percentage of noncompliance with this standard has increased, rising to approximately 50% of healthcare facilities in 2015.

These breaches are specific to HLD of semicritical devices and sterilization of critical devices, which can pose a risk of infection to patients.

 

Need for expertise

Disinfection and sterilization processes continue to become more complex. As instrumentation becomes more sophisticated, the sterilization and HLD practices are more prescriptive, new processes are developed and introduced to healthcare facilities, and the detailed IFUs for these methods can be difficult to follow.

New regulations, standards, and guidelines are constantly being published, and keeping up with them is time consuming and requires a foundation of knowledge of these practices.

Coordinating the IFUs between the medical device manufacturer and disinfectants or sterilizer requires the kind of subject-based knowledge and critical thinking skills that a SME can provide.

For example, in October 2015 the CDC and FDA issued a Health Update about the Immediate Need for Healthcare Facilities to Review Procedures for Cleaning, Disinfecting, and Sterilizing Reusable Medical Devices because of infection control lapses due to noncompliance with recommended reprocessing procedures. They recommended that facilities immediately engage an expert in sterilization and HLD to assess their reprocessing procedures.

This assessment was meant to ensure that reprocessing is done correctly, including allowing enough time for reprocessing personnel to follow all steps recommended by the device manufacturer.

 

Need for oversight

The Joint Commission’s Competency & Training section Standard LD.03.06.01-EP 4 states: Those who work in the hospital are competent to complete their assigned responsibilities.

High-level disinfection and sterilization are complex processes (with multiple important steps) that require front-line staff and those responsible for its oversight to be competent and trained initially and on an ongoing basis as defined by the organization.

To help healthcare facilities meet the sterilization and disinfection requirements, the Joint Commission issued a BoosterPak for HLD and Sterilization. The BoosterPak provides detailed information on these processes and discusses the importance of having an individual with sterilization and HLD knowledge in several standards and elements of performance, ie, the SME.

The Joint Commission’s leadership standard LD.04.01.11 states: The organization makes space and equipment available as needed for the provision of care, treatment, and services.

• EP2: The arrangement and allocation of space supports safe, efficient, and effective care, treatment and services.

• EP4: The grounds, equipment, and special activity areas are safe, maintained, and supervised.

• EP5: The leaders provide for equipment, supplies, and other resources.

• Leaders at each program, service, site, or department are responsible for the care, treatment, and services provided.

• Leaders develop policies and procedures that utilize medical equipment, devices, and supplies that require high-level disinfection (HLD) and sterilization prior to use on patients.

• There should be clearly defined, written, managerial and/or supervisory oversight that includes knowledge and training of (HLD) and/or sterilization at the leadership level (this will provide safe and effective HLD and sterilization processes).

• Managerial staff have knowledge of and use evidence-based guidelines to develop education, training, and competency for high-level disinfection and sterilization.

 

Ensuring compliance

Processing medical devices requires knowledge of the processes, standards, and regulations, medical device design, packaging, sterilizers or disinfectants, and the processing environment.

In some instances, there may a conflict between the IFU of an instrument, sterilizer, or packaging method. To resolve such conflicts, a multidisciplinary team led by the SME should conduct a risk assessment to determine which IFU to follow.

Transport and storage of medical devices also has been the cause of noncompliance in some facilities.

Contaminated items must be labeled and transported according to the Occupational Safety and Health Administration’s Bloodborne Pathogens regulation to prevent contamination to the environment or staff.

To prevent cross-contamination, the user of the items must be able to distinguish between a used or contaminated piece of equipment and a patient-ready piece of equipment.

Similarly, the Environmental Protection Agency regulates disinfectants, and the Department of Transportation has certain regulations for cases in which items with bloodborne pathogens are transported outside of a healthcare facility.

Some healthcare facilities have begun to use SMEs to ensure compliance with IFUs and standards, and to review employee training and competencies.

SMEs are involved in decisions about new product implementation to ensure safe, effective use. Finally, SMEs also facilitate standardization of sterilization and disinfection policies and procedures to ensure compliance throughout the entire facility. ✥

 

 

References

Association for the Advancement of Medical Instrumentation. Preventing device-related healthcare-associated infections: Issues and outcomes from the September 2016 forum, Medical Technology and HAIs. https://s3.amazonaws.com/rdcms-aami/files/production/public/FileDownloads/Summits/161227_AAMI_HAI_Forum_Report.pdf.

Centers for Disease Control and Prevention and Food and Drug Administration. Health update about the immediate need for healthcare facilities to review procedures for cleaning, disinfecting, and sterilizing reusable medical devices. October 2015. https://emergency.cdc.gov/han/han00383.asp.

Joint Commission. High-level disinfection (HLD) and sterilization BoosterPak. 2015. http://www.airforcemedicine.af.mil/Portals/1/Documents/DECS/InfectionPrevention_Control/Resources/Guidelines/The_Joint_Commission_HLD_Sterilization_Booster_Pak.pdf.

Seavey, R. CS departments need an SME with critical thinking skills. Communiqué 2017;Jan/Feb, 82-83. https://www.iahcsmm.org.