A patient needs major surgery to remove 5 laparotomy sponges left behind during a previous case. The investigation finds that during an exploratory laparotomy, the circulating nurse introduced a 5-pack of sponges into the sterile field but did not enter the count on the worksheet or white board. Relief staff were not aware of the extra 5 sponges, and the count later appeared correct. The incident is 1 of 6 retained-item cases that resulted in $25,000 fines for California hospitals in September 2009.
What does it take to eliminate the rare but stubborn problem of retained items?
Though the incidence is unknown, estimates are that an item is left behind in from 1 in 1,000 to 1,500 abdominal operations and 1 in every 8,000 to 18,000 inpatient operations.
Medicare has a policy to no longer pay an additional amount for treatment associated with retained surgical items. Insurance companies have followed suit.
Could technology such as bar-coded or radiofrequency tagged sponges help prevent retained items? Three technologies are available (sidebar, p 9).
OR leaders whose facilities have adopted technology caution that it is not a substitute for manual counting and other preventive measures.
“This is a big change in OR culture, and it cannot just be thrown into the OR without preparation for everyone,” says Robert Cima, MD, MA, chair of the surgical quality committee at the Mayo Clinic in Rochester, Minnesota. The Clinic has introduced scanning of bar-coded sponges as part of a 4-year project to prevent retained items (related article, p 12). How the technology is implemented and the culture into which it is introduced are more important than the technology itself, he notes.
Leaders in organizations that have adopted sponge-tracking technology stress these common themes:
A recent study Dr Cima led at Mayo found communication breakdowns were the most common root cause of retained items.
“The technology is great, but it doesn’t take the place of counting—and you have to communicate with each other,” stresses Cheryl Weisbrod, RN,
MS, nurse administrator of surgical services at the Mayo Clinic in Rochester. The real work is “to change the behavior of the nurses and surgeons to have them work together,” adds Verna Gibbs, MD, a surgeon who developed the No-Thing Left Behind campaign to prevent retained items (sidebar, p 10). She is a professor of clinical surgery at the University of California, San Francisco (UCSF) and a surgeon at the San Francisco Veterans Affairs Medical Center.
The UCSF Medical Center adopted the bar-coded sponge technology (SurgiCount Medical) more than 2 years ago as part of a multidisciplinary effort.
Perioperative nurses at UCSF also worked with Dr Gibbs in developing a standardized low-tech method for verifying that all sponges are accounted for. The method, called the Sponge ACCOUNTing system, uses inexpensive plastic hanging sponge holders and dry erase boards to keep track of sponges. (See September 2008 OR Manager.)
The use of the hanging sponge holders adds about 30 cents per holder to total case costs, Dr Gibbs says.
Sandra Wienholz, RN, MSN, patient care manager in the Moffitt Long ORs at UCSF, says, “Nurses have to be very confident in their practice before you add technology. As our technical and patient care responsibilities increase, our sponge counting practice has to be strong.” (At the time UCSF adopted barcoded sponges, technologies using radiofrequency energy had not yet been cleared by the Food and Drug Administration.)
One benefit of the bar-coded sponge system is that it has empowered the nurses, Wienholz says. When there is a count discrepancy, nurses can be more confident that a missing sponge might still be in the patient.
A recent example was an early-morning case. At the end of the case, the barcoding system showed a missing sponge. After a thorough inspection by the staff of the back table, floor, and garbage, the sponge was not recovered.
“They were pretty adamant with the surgeon that it still had to be in the patient,” Wienholz says. The surgeon called for an x-ray and conducted a manual wound exploration, locating the sponge.
Cohesive teamwork, aided by technology, averted a retained sponge, she says.
Since introducing bar-coded sponges, Wienholz says OR nurses at UCSF have been able to predict with 100% accuracy items that would have been retained.
She estimates the system’s costs at about $10 to $15 a case. “That may seem like a lot if you do a large number of cases, but if you can avert one retained item, you pay for it,” she says.
The hanging sponge holder bags have also been useful, she notes. “Now a relief nurse can walk into a room, and it is clear where you are in your counts.”
Collaborating with surgeons and the radiology department is crucial to a successful implementation, Wienholz comments.
“If the physicians don’t see the importance of counts and aren’t willing to allow the nurses to get the technology up and running, the staff will be forced to find shortcuts,” she says. “It really comes down to the nursing staff feeling they have a sense of ownership of their practice and the technology.”
Collaborating with the radiology department is also important. Because the bar-coding system can alert nurses to miscounts, intraoperative x-rays to rule out a retained item may be more common.
The ORs at the Hospital of the University of Pennsylvania in Philadelphia have been using the RF Surgical Detection System since 2007. The system consists of a handheld scanning wand and radiofrequency-tagged gauze, sponges, and towels.
The technology is an additional patient safety feature. Nurses count as usual. The wand is used for all open cavity cases or when there is a count discrepancy.
If a sponge is not detected in the body cavity, the wand can be swept over the trash and linen carts, notes Marianne Saunders, RN, BSN, CNOR, nurse manager of perioperative services.
In one example, the wand helped locate a sponge in an unlikely spot during an orthopedic case. Normally, wanding isn’t necessary during orthopedic cases, but the staff nurse had counted multiple times and not found the sponge. As the wand passed over the area, the system alarmed, and the sponge was found under the bed in the foot pedal of a drill.
Dr Gibbs comments that she views the wand as an adjunct to the methodical wound exam, adding that the “wand should be used by the surgeon in all cases if you are not going to use a standardized manual counting system.”
The University of Pennsylvania was one of the first to implement the RF Surgical Detection System. Initially, there were some frustrations, says Saunders, which she and her team worked through with the company’s engineers. At first, wands alarmed if they touched metal on the back table or got too close to staff members’ RF-tagged ID badges. The engineers adjusted the signal and replaced the consoles that control the wands, which fixed the problem.
Gary Blackbourn, RF Surgical’s vice president for sales and marketing, explains that the RF tags on the sponges and on ID badges emit signals that are similar but not the same. The problem was fixed by tightening the signal in the RF Surgical software. He says the company has not had issues with the RF system reacting to ID badges for about 1 to 1½ years.
The wand is now marketed for 24-hour use. Saunders explains that when the staff turns on the console and opens the wand, they label the wand, and it is good for 24 hours. The staff must be educated not to unplug the console between cases. If the console is unplugged for more than 2 minutes, use of the wand is lost, and a new one must be opened.
Saunders says education was also needed for the physicians on the new RF system. According to policy, wanding is performed for open cavity cases or when there is a count discrepancy. Though wanding takes less than a minute, some physicians perceive it as a delay.
Extensive education is needed before the system is implemented, Saunders advises.
“We rolled it out to everyone beforehand,” she says. Stations were set up so all personnel could participate in demos. “We did demos for weeks.” In addition, mass e-mails were sent to attending physicians, fellows, and residents. The chief of surgery sent a memo supporting the initiative, which was also supported by the senior administration.
–Pat Patterson
The California violation reports were posted September 3, 2009, by the California Department of Public Health website at www.cdph.ca.gov. Look under News Room.
Cima R R, Kollengode A, Garnatz J, et al. Incidence and characteristics of potential and actual retained surgical object events in surgical patients. J Am Coll Surg. 2008;207:80-87.
Gawande A A, Studdert D M, Orav E J, et al. Risk factors for retained instruments and sponges after surgery. N Engl J Med. 2003;348:229-235.
Gibbs V C, Coakley F D, Reines H D. Preventable errors in the operating room: Retained foreign bodies after surgery. Current Problems Surg. 2007;44:281-337.
Gonzales-Ojeda A, Rodrigues-Alcantar D A, Arenas-Marquez H, et al. Retained surgical bodies following intra-abdominal surgery. Hepatogastroenterology. 1999;46:808-812.
Estimates are that a foreign body is retained:
–Gawande A A, Studdert D M, Orav E J, et al. N Engl J Med. 2003;348:229-235.
–Gonzales-Ojeda A, Rodrigues-Alcantar D A, Arenas-Marquez H, et al. Hepatogastroenterology. 1999:46:808-812.
In a study at the Mayo Clinic in Rochester, Minnesota, the actual rate of retained items was 1 in 5,500 operations. Postoperative x-rays are routinely performed for open-cavity cases.
–Cima R R, Kollengode A, Garnatz, J et al. J Am Coll Surg. 2008;207:80-87.
The weak link in preventing retained foreign bodies is the deceptively correct count—72% to 88% of retained items happen in operations with “correct counts.”
–Regenbogen S E, Greenberg C C, Resch S C, et al. Surgery. 2009;145:527-535. (References 9-12)
Standard sponge counting alone is predicted to prevent about 82% of retained sponges, or a rate of 12 retained sponges per 100,000 operations.
With use of bar-coded sponges, the estimated rate of retained objects is 1 in 60,000 operations, or 1.7 per 100,000.
–Regenbogen S E, Greenberg C C, Resch S C, et al. Surgery. 2009;145:527-535.
Steps to prevent retained items
NoThing Left Behind campaign

Hanging sponge holders.
Surgeons
Nurses
Radiologists
Source: Verna C. Gibbs, MD.
Checklist
Audit at the end of everycase.
ClearCount Medical Solutions
The system, which combines sponge accounting and detection, consists of a bucket with scanner, RFID-tagged sponges, and scanning wand. Sponges are scanned in and out of the case. If there is a discrepancy, the patient is scanned with the wand to detect any remaining sponges. The system is cleared by the Food and Drug Administration (FDA).
Costs: ClearCount estimates the cost per case at $25 to $35, including hardware and disposables. The hardware is offered as a rental. Disposable costs include a sterile sheath for the reusable wand plus the RFID-tagged sponges.
Installations: ClearCount announced its first installation in June 2009 at Memorial Sloan-Kettering Cancer Center in New York City.
RF Surgical Systems, Inc
The system has 3 components: A handheld scanning wand connected to a console and micro radiofrequency (RF) tags embedded in gauze, sponges, and towels. When the wand is passed over a patient, an alarm signals the presence of any retained RF-tagged item. The system can be used to locate missing sponges elsewhere in the OR. The system was cleared by the FDA in 2006.
Costs: Costs include $50 for the wand, now marketed for 24-hour use in each OR. On average, a wand is used for about 3 cases per day, the company says. RF-tagged sponges cost about 20 cents more than conventional sponges. A sterile wand sleeve is also needed. The consoles are provided on loan.
The company estimates the cost at about $15 per case if averaged across all of a hospital’s surgical cases.
Installations: About 75.
SurgiCount Medical, Inc
The system includes bar-coded sponges and towels, a scanner, and software for documenting counts and generating reports.
Sponges and towels have unique bar codes. Sponges are scanned and recorded during initial and final counts. The system was cleared by the FDA in 2006.
Costs: The incremental cost per procedure is estimated at $12 per procedure by the company. The only incremental cost is the bar-coded sponges, according to Cardinal Health, the distributor. The hardware (scanner/computer, mount for IV pole, charger, and extra battery) is available at no charge.
A cost-effectiveness model developed by Harvard researchers found barcoded sponges were the only technology with a cost-per-event prevented in a range acceptable to most institutions (Regenbogen S E, Greenberg C C, Resch S C, et al. Surgery. 2009;145:527-35). Marketing models for the RF systems have been modified since the study was conducted.
Installations: Number of installations not disclosed.