November 1, 2011

High-throughput OR pod expedites patient flow

By: OR Manager
Share



OR Manager; Vol. 27 No. 11; November 2011



A new high-throughput OR pod at Massachusetts General Hospital (MGH) in Boston is designed to expedite patient flow and make the most of the OR’s resources during regular weekday house. The 4-OR pod with 13 perianesthesia bays is part of a 28-OR department opened in Fall 2011 in a new inpatient building. The pod is configured to support parallel processing, with certain tasks such as anesthesia induction and room setup performed in tandem.

“We felt that if we could maximize the use of parallel processing, we could reduce the time it takes to turn over cases safely,” says Lisa Morrissey, MBA, RN, CNOR, nursing director for the main OR.

The pod’s initial case-load will be elective general surgery, with procedures such as laparoscopic cholecystectomy and thyroidectomy.

The second floor of the new OR department at Massachusetts General features a 4-OR high-throughput pod. The pod is configured to support parallel processing.

OR of the Future experiment

The new pod is based on the MGH OR of the Future experiment, reported in 2005 and 2006, which tested ways to improve patient throughput. In the experiment, the researchers constructed an OR suite that included an induction room, an OR, and an early recovery area. They then compared throughput for the experimental OR and a conventional OR.

Results showed that surgeons performing the same mix of cases in the experimental OR processed more cases in a day and used less time per case. Nonoperative time was reduced from 67 minutes to 38 minutes in the experimental OR, and operative time was reduced by about 5%. Though hospital and anesthesia costs per case increased, the improved throughput offset the costs, and the global net margin was unchanged.

High-throughput features

Among features of the new pod that expedite patient flow:

  • The perianesthesia bays are set up to be used for preoperative assessment and postanesthesia recovery and are staffed by nurses cross-trained for both functions. The bays provide for privacy but have a central nurses’ station for the monitoring of patients.

    “We can be preparing our preop patients and recovering patients at the same time,” Morrissey notes.

  • Two bays are outfitted with anesthesia gases, enabling them to be used for anesthesia induction. These bays are located directly across from the OR suite, so patients can be moved directly to the OR while asleep.
  • The pod’s 4 ORs are arranged around a central core. Between each pair of ORs is a setup room where the staff can set up instrument tables for the next procedure. “That allows us to make sure we have all of the equipment and instruments laid out,” says Morrissey. “We can do the counts before the patient comes into the OR.”
  • A clinician workstation between each pair of ORs, with windows facing into the OR, is a place for clinicians to work as cases are finishing and the room is cleaned.
  • Preference cards were revised, reviewed by surgeons, and updated in the information system. That helps to ensure accurate case setup and reduces delays.
  • General surgery instrument trays and supplies are being standardized to the extent possible given the number of subspecialties at this large teaching hospital.
  • A preprocedure huddle will be held immediately before each case so the surgical team can discuss any additional information and supplies needed.

One of the new operating rooms at Massachusetts General. The new 28-OR department opened in Fall 2011.

The pod’s staffing model

Additional resources and different role groups are needed for the new format, Morrissey notes.

In addition to cross-trained preop and perianesthesia nurses, OR assistants have been trained in the opening of sterile supplies. One assistant will be assigned to each pair of ORs. After the surgical technologist (ST) checks the preference card for the next case, the assistant can open supplies while the ST scrubs.

Setting up in advance

The pod’s design allows instrument tables to be set up in advance of the next case, Morrissey notes. The tables are set up in an area with windows adjacent to the ORs.

AORN recommends setting up sterile fields as close as possible to the time of use and observing them continuously. AORN also advises preparing the sterile field in the location where it will be used and not covering it.

The MGH cardiac service historically has set up its tables prior to the next case, Morrissey notes.

“We have not changed that practice, and we have not had negative results related to infection,” she says. “In fact, we find that being able to set up in advance allows us to make sure we have all of the items we need available for the procedure.”

Based on the favorable experience in the cardiac service, she adds, “We felt this would be an important part of parallel processing. Having the space allows us to do [the setup] away from the patients and surgery.”

References

AORN. Recommended practices for maintaining a sterile field. Perioperative Standards and Recommended Practices. Denver, CO: AORN, 2011.

OR of Future reports improved throughput. OR Manager. 2006;22(1):10-11.

Sandberg W S, Daily B, Egan M, et al. Deliberate perioperative systems design improves operating room throughput. Anesthesiology. 2005;203:406-418.

Stahl J E, Sandberg W S, Daily B, et al. Reorganizing patient care and workflow in the operating room: A cost-effectiveness study. Surgery. 2006;139:717-728.