February 17, 2017

Arm your staff with strategies to prevent HAIs

By: OR Manager
Share

Each year, more than 700,000 patients in acute care hospitals fall prey to healthcare-acquired infections (HAIs), and approximately 75,000 hospitalized patients die from them. Such statistics have gotten the attention of regulatory agencies that are determined to reduce these numbers.

The Healthcare-Acquired Infections and Medical Technology Stakeholder Event held in September 2016 examined the relationship between the use of healthcare technology and the occurrence of HAIs, as well as best practices for avoiding infections.

The summit was hosted by the Association for the Advancement of Medical Instrumentation (AAMI) in conjunction with the Food and Drug Administration, Centers for Disease Control and Prevention, American Hospital Association, and the Joint Commission.

Representatives from major stakeholders’ organizations such as the International Association of Healthcare Central Service Materiel Management (IAHCSMM), regulators, healthcare technology management professionals, and representatives from accreditation bodies attended the summit.

They sought to ascertain the role that medical devices and equipment play in transferring pathogenic organisms from a host individual to others—either directly or by dispersing organisms into the healthcare environment.

Attendees investigated how medical device design, instructions for use, cleaning, disinfection, reprocessing, equipment maintenance, personnel practices, human factors, training, facility design, and management practices contribute to HAIs. They identified where transmission hazards exist and what can be done to minimize those hazards.

Before the HAI summit, surveys were distributed to all stakeholders to obtain information about the critical issues surrounding HAIs caused through the use of medical devices and other healthcare technology. The highest number of responses came from the reprocessing stakeholders. Results from this survey were referred to throughout the summit.

To better understand the issues and to identify solutions, the workshop was broken into three breakout sessions that examined:

  • Things—How do aspects of devices and equipment and associated activities (eg, maintenance and reprocessing) contribute to the problem?
  • People—How do human behavior and the social environment of care (eg, patients, staff, management, and the public) contribute to HAI transmissions?
  • Places—How does the physical environment of care (eg, facilities, patient care environment, and governance) contribute to the problem of device-involved HAIs?

Things

The overall conclusion from both the surveys and the working group was that medical device designs pose the biggest challenge. That’s because the design of many medical devices does not necessarily account for reprocessing. Complex designs require devices to be disassembled for cleaning and then reassembled. Many devices have numerous parts, nooks, and crannies that are difficult to clean. Some devices have touch screens and bar scanners that cannot tolerate disinfectants.

Instructions for use (IFUs) also were rated as a major cause of HAIs. Some are written for a regulatory audience or to mitigate liability without regard for usability. The language is either unclear or so complex that IFUs generally aren’t read or are left open to interpretation. There is no standardization of format or instruction language. Sometimes the font size is too small to read.

There are also conflicting IFUs in that directions from the medical device manufacturer may differ from how the equipment is actually processed. The ability to thoroughly clean and disinfect or sterilize a medical device is affected by all of these factors.

Healthcare facility staff who perform reprocessing should be involved in the decision making process so that they can voice any concerns about the equipment needed for reprocessing, the time involved, and the competency requirements.

Reprocessing must be performed by staff who have been trained to follow IFUs, and they should have standardized cleaning protocols.

New in healthcare facilities is a quality reprocessing management system that will develop a feedback mechanism to key stakeholders. Once the new AAMI standard on its implementation is established, more information will be provided in a future OR Manager article.

 

People

The group identified numerous transmission risks attributable to human behavior and the social environment of care. Healthcare workers have a tendency to become desensitized to the fact that they can potentially transmit HAIs. Because of the high volume of instruments needed, staff may take shortcuts.

Not all central sterile services (CSS) technicians receive adequate training, and other problems such as language barriers or lack of knowledge about the use of personal protective equipment (PPE) can contribute to HAIs. Movable medical devices may not be cleaned or disinfected if no one is specifically assigned that task.

Patients can infect their own personal devices as well as those of other patients by sharing their personal items. Furthermore, they may not be aware at the time of discharge that they may be carriers of pathogens.

Environmental services (EVS) staff sometimes feel they are left out of the loop and given little feedback as they try to quickly turn over rooms. Some facilities noted that there is a lack of EVS authority, problems such as general competency and education, and lack of understanding of PPE and procedures.

Those in governance and leadership positions also play a role in HAIs because they do not necessarily support EVS or regard CSS staff as an integral part of patient safety.

Staff who are afraid of being penalized for taking time off from work because of illness may come to work sick, thus potentially spreading infection.

Some department managers, especially those in EVS and CSS, may lack the training and knowledge needed for building and presenting a business case to justify additional resources.

Failing to consider the requirements for processing during the purchasing process impacts the ability to properly clean and disinfect or sterilize the medical device because the necessary equipment, competency, and time may not be available. Manufacturers show caregivers how to use their products, but they don’t always educate CSS staff.

 

Places

Some facilities are still struggling with a design that does not support appropriate workflow. Aging facilities are not easy to retrofit. Some areas are not designed for reprocessing, and some reprocessing areas are repurposed rooms.

Some HVAC systems have inadequate airflow (positive/negative pressure), leading to air droplet contamination. It can be difficult to monitor and maintain the correct humidity levels and temperature, as well as ensure that filters are changed frequently.

Resources are needed to solve such problems, and stakeholder buy-in is essential for redesigning existing space, upgrading equipment, identifying one-way directional instrument flow, installing proper ventilation, and creating a physical separation for clean vs dirty instruments.

Whether renovating an existing facility or building a new one, it’s important to use an evidence-based design and to involve staff who will be working in this area.

An infection preventionist should review furniture, equipment, and other surfaces to ensure they meet criteria for infection prevention.Action items

Action Items

Reducing HAIs will require changing the culture in healthcare facilities, improving communication, and implementing a zero tolerance policy for failure to adhere to policies and procedures. Entry-level educational requirements should be established, and both facility leaders and manufacturers should provide education and training.

Patient education should include all aspects related to HAIs and their surgical procedure. In addition, discharge planning should include infection prevention. Patients also need to be encouraged to be forthcoming with medical history and informed that they can potentially be carriers of pathogens.

A higher value should be placed on the EVS technician position. Use of appropriate PPE should be included in EVS staff training.

There should be a dedicated EVS person for specific units and types of areas. Movable medical devices should be centrally controlled and cleaned by a designated trained person.

In addition, EVS staff should be included in routine meetings and rewarded for good performance.

Healthcare leaders can take the following actions to reduce HAIs:

  • have realistic expectations (eg, move away from the “we want it in 5 minutes” mentality)
  • understand the importance of low-level jobs that may contribute to a higher number of HAIs
  • involve reprocessing staff in purchasing decisions
  • provide adequate staff relative to volume
  • have a policy that no instruments should be trialed without an IFU
  • allow healthcare workers to stay home when they are sick, without fear of penalty
  • benchmark and implement best practices instead of minimum requirements, and implement best case requirements.

Conclusions

The main take-home points of the summit were to place greater emphasis on staff education and competency, and include reprocessing staff when deciding to buy new instruments or equipment. Policies and procedures should be developed for infection prevention, and staff should be held accountable for complying with those guidelines. ✥